Feature Updates

New Features

The units of a timer support singular and plural forms.

Improvements

...

Network detection configuration

Improvements

      • 4G self-recovery
      • When an image sent from the control computer is damaged, it will be skipped.

Fixed Problems

ProblemCause

Media download status is abnormal in a poor network.

A lack of fault tolerance mechanism

When the terminal storage is full, media cleanup will delete the thumbnails in VNNOX at the same time.

No judgement for the thumbnails in VNNOX during media cleanup

When a solution are played more than two days during the specified period, the screen goes black occasionally.

Beyond the schedule, redundant messages are sent every second during terminal scheduling, which affect message mechanism.

When the synchronous playback and RF time synchronization are enabled, after you power off and restart the terminal, and publish a solution to play, two solutions are played at the same time.

Enabling synchronous playback will restart the terminal. The handling process is not consistent with the process of restarting terminal upon power failure and not locked.

Grayscale loss occurs occasionally when the T1 and T2 play solutions.

The FPGA has a defect.

When a text solution is played in the copy and play mode through USB drive, after the text properties of the solution are modified, the solution is exported again and the old solution is overwritten, the terminal does not play the modified solution.

When text properties are modified but the file size is not changed, the terminal identifies that the solution is not changed.

Remaining Problems

ProblemRemedy

Underlines of text are not displayed properlyHDMI preferred does not take effect occasionally after the terminal is restarted.

This problem is being fixed. If necessary, please contact the technical support team of NovaStar.

When terminals fail to register at NovaiCare because the number of terminals exceeds the authorized number, the terminals still send requests to the serverAfter media cleanup, the disk space is not released occasionally and the space size read by the control computer does not change.

This problem is being fixed. If necessary, please contact the technical support team of NovaStar.

...